Anuchlor CZP 500
High Build Chlorinated Rubber Primer
Product Description
Anuchlor CZP 500 is
a high performance high build primer for structural steel surfaces based on
plasticised chlorinated rubber and pigmented with zinc phosphate rust inhibiting
pigment. It can be applied on manually cleaned steel surfaces where blast
cleaning is either impractical or cost-restrictive. It can be overcoated with
conventional and chlorinated rubber topcoats.
Features and Benefits
![]() |
Easy
to apply and can be applied via airless spray, conventional spray and brush.
|
![]() |
While
inferior surface preparation can never be recommended, Anuchlor CZP 500 has
shown to tolerate though with shorter life, power-tool and hand-cleaned
steel. |
![]() |
Renders
hard, inert film showing excellent resistance towards dilute acids, alkalis,
certain salts, oxidizing agents, aliphatic hydrocarbons, alcohols, mineral
oils, greases etc. |
![]() |
Extremely
durable and weather resistant. |
![]() |
Non-toxic
and cost-effective. |
![]() |
Has
very low water and water vapour permeability. |
![]() |
Suitable
for varied end applications i.e. ideal for high humidity, moisture, marine
atmospheres, heavy rains, high temperatures, damp conditions, very dusty and
fungus prone conditions. |
![]() |
Impart
excellent inter-coat adhesion properties. |
Fertilizer plants |
Sewage farms |
Concrete Storage Tanks |
Water Treatment Plants |
Structural Steel |
Galvanized Iron |
Bleacheries and laundries |
Breweries |
Pulp and Paper Mills |
Chemical Plants |
Marine and shore installations |
Swimming Pools |
Food Processing Plants |
Areas of excessive moisture |
Petro-chemical Plants |
Refineries |
Surface Preparation:
Steel
- The
surface should be blast cleaned to SSPC-SP 10-63T
or NACE No. 2 i.e. loose rust and scales, dirt, grease, oil,
paint, wax, weak oxide films and other contaminants should be removed. It means
that at least 95% of any given square inch has the appearance of white metal
and the remainder is limited to slight discolourations. Blast cleaning to SSPC-SP
5-63 or NACE No. 1 is
recommended where heavy corrosive conditions exist. That means a surface with a
grey metallic colour, slightly roughened to form a suitable anchor pattern for
coatings. This surface is free of all oil, grease, dirt, mill scale, rust,
corrosion products, oxides, paint and other foreign matter. In absence of blast
cleaning, prepare the metal surface by wire brushing, sanding, grinding,
scrapping or chipping with hand or power tools. Remove all the contaminants.
Apply a coat of Anuchlor CZP 500 followed by 2-3 coats of Anuchlor
555 LB Chlorinated Rubber Enamel. Anuchlor - MIO can be used as
intermediate coat depending on service requirements.
Galvanized Iron - Remove dirt, dust, oil, old paint etc. Degrease the surface with degreasing solvents like xylene or tri-chloroethylene. Apply one coat of Anuprime - 291 Wash Primer for obtaining maximum adhesion. Apply one coat of Anuchlor CZP 500 followed by 2-3 coats of Anuchlor 555 LB. Anuchlor - MIO can be used as an intermediate coat depending on service requirements.
TECHNICAL DATA
Name/Description |
Anuchlor CZP 500 |
Type |
Single pack cold cured |
Composition |
Chlorinated rubber / Zinc Phosphate |
Colour |
Grey and Red |
Finish |
Smooth and Matt |
Volume Solids |
38 ± 3% |
Dry film thickness per coat |
50 microns |
Coverage-(theoretical-no loss) |
7.6 m² /litre |
Serviceability @ 30° C - Dry to touch - Re-coat by Spray - Re-coat by Brush - Full Cure |
30 - 45 minutes 2 hours 16 -24 hours 7 days |
Relative Humidity |
90% |
Application Temperature - minimum - maximum |
4°
C 35° C |
Dry heat resistance |
65° C |
Solvent/Thinner |
Anusol - CRT Thinner |
Flash Point |
25° C |
Packing |
4 & 20 litres |
Shelf Life |
6 months |
Precaution |
Flammable. Keep away from heat and open flame. Maintain good ventilation and avoid breathing vapours. |
Product Limitation:
![]() |
Anuchlor
CZP 500 is not resistant to most
solvents, animal and vegetable oils and fats common in dairies, packinghouses
and sewage treatment facilities. |
![]() |
Do not use on
floors. |
![]() |
Epoxy and
polyurethane topcoats are not suitable. |
Notes
![]() |
Brushes and spray equipments
should be cleaned with Anusol - CRT Thinner. |
![]() |
The contents should be stirred thoroughly prior to use. |
![]() |
When overcoating the weathered or aged Anuchlor CZP 500,
ensure that the coating is fully free from all contamination such as
oil, dust, grease, stains etc. |
![]() |
This coating should always be thinned with Anusol - CRT Thinner. The use of alternative thinners can severely inhibit the curing mechanism of the coating. |
Disclaimer:
Information provided herein
is based upon tests believed to be reliable. It does not guarantee the results
to be obtained. Nor does it make any express and implied warranty or
merchantability, or fitness for a particular purpose concerning the effects or
results of such case. It does not release you from the obligation to test the
products supplied by us as to their suitability for the intended uses. The
application, surface preparation and use of the products are beyond our control
and, therefore, entirely your own responsibility.